China Single NH3 Gas Sensor - China Supplier
China Single NH3 Gas Sensor - China Supplier China Single NH3 Gas Sensor - China Supplier China Single NH3 Gas Sensor - China Supplier China Single NH3 Gas Sensor - China Supplier China Single NH3 Gas Sensor - China Supplier

Single NH3 Gas Sensor

Price: 550
Industry Category: Electronic Components & Supplies/Sensors/Gas Sensors
Product Category:
Brand: BSA/QT
Spec: BSA/QT-BJ


Contact Info
  • Add:Room 405, 4th Floor, Xijun Building, No. 4 Shangxue Road, Xinxue Community, Bantian Subdistrict, Longgang District, Shenzhen, Zip: 518100
  • Contact: 黃工
  • Tel:0755-28680671
  • Email:

Other Products

Description
Additional Information

Intelligent Ammonia NH3 Gas Sensor

The Bestan Intelligent Ammonia NH3 Gas Sensor is an intelligent sensor launched mainly for gas equipment manufacturing enterprises, including industrial process gas control equipment, environmental monitoring gas equipment, gas analysis instrument equipment, etc.; it is developed and produced mainly to solve problems such as the wide variety of gas detection types, incompatibility of gas sensors, complex production calibration, and limited development and replacement.

By adopting the intelligent Hydrogen Sulfide H2S sensor module developed by our company, you only need to develop one product to meet the monitoring needs of more than two hundred kinds of toxic and harmful gases, and the production and replacement processes are simple, without the need for re-molding, greatly reducing the enterprise's R&D costs, production costs, and after-sales costs.

At the same time, the sensor is easy to operate, accurate in measurement, and reliable in work, suitable for different requirements of industrial field or laboratory measurement. The sensor features simultaneous voltage and serial output, facilitating customer debugging and use.

The Intelligent Ammonia NH3 Gas Sensor is based on high-precision gas-sensitive elements, converting the weak output signal of the sensor into standard signals that are easier for customers to apply, such as 0~5V, 4~20mA, TTL, RS485, etc. The intelligent gas sensor has been calibrated and tested before leaving the factory; customers can directly collect signals for use; meanwhile, it has a small package volume, detects many types of gases, and has a unified structure, facilitating customer direct use or secondary development needs.

The Intelligent Ammonia NH3 Gas Sensor is a product launched to adapt to current gas detection needs. The sensor processes the output signals of sensors with various different detection principles through professional high-precision amplification circuits with noise-free processing, temperature compensation, high-purity gas calibration, and other steps, converting gas concentration signals into standard digital and analog signals. Users do not need to deal with complex and tedious gas detection principles, detection types, calibration difficulties, and other issues; they can directly use the gas sensor and read accurate gas concentration information.

Product Features

Intrinsically safe circuit design, supports hot-swapping;

Compatible with electrochemical, infrared, catalytic, semiconductor, PID photoionization and other principle sensor elements;

Unified structure, same communication, capable of detecting over 1000 types of gases;

Simultaneous output of digital and analog signals, convenient for customer debugging and use;

Built-in temperature and humidity compensation, factory calibrated, ready to use;

Small size, high precision, easy communication;

Comes with professional testing software, supports self-calibration and calibration

Recommended Detection Parameters

<

Detection types exceed 100 kinds, welcome to call for consultation on other parameters!!

Detection Factor

Detection Range

Resolution

Detection Accuracy

Detection Principle

Carbon Monoxide CO

0-1000PPM

0.1PPM

≤±2%FS

Electrochemical

Oxygen O2

0-25%VOL

0.01%VOL

≤±2%FS

Electrochemical

Hydrogen Sulfide H2S

0-1000PPM

0.1PPM

≤±2%FS

Electrochemical

Combustible EX

0-100%LEL

0.01%LEL

≤±2%FS

Electrochemical

Methane CH4

0-100%LEL

0.01%LEL

≤±2%FS

Electrochemical

Sulfur Hexafluoride SF6

0-3000PPM

1PPM

≤±2%FS

Electrochemical

Ammonia NH3

0-100PPM

0.1PPM

≤±2%FS

Electrochemical

CL2

0-10PPM

0.01PPM

≤±2%FS

Electrochemical

Detailed Technical Parameters

1) Operating Voltage: DC5-12V-24V±1%;

2) Operating Current: Specific depending on detection principle;

3) Measured Gases: Toxic and harmful gases, flammable and explosive gases, volatile organic compounds;

4) Installation Method: Plug-in type, fixed type, external type;

5) Measurement Range: Selected according to requirements;

6) Detection Principle: Electrochemical/Infrared/Semiconductor/Thermal Conductivity/Optical PID, etc., selected according to environment

7) Resolution: 0.001, 0.01, 0.1, 1ppm;

8) Response Time: <10s

9) Sampling Accuracy: ±2%FS;

10) Warm-up Time: 30s;

11) Repeatability: ±1%FS;

12) Long-term Zero Drift: ≤1%FS/year;

13) Operating Temperature: -20~55℃;

14) Operating Humidity: 10~95%RH (no condensation);

15) Storage Temperature: -40~70℃;

16) Operating Pressure: 86kPa~106kPa;

17) Housing Material: Aluminum alloy/Stainless steel;

18) Output Interface: Optional;

19) Service Life: Electrochemical more than 2 years; Infrared more than 5 years;

20) Warranty Period: 1 year

21) Output Voltage: 0.4-2.0VDC (standard), 4-20mA, TTL, RS485, etc. optional;

22) Dimensions: Square/Cylindrical structure;

23) Comes with professional communication software.

Detection Reference Basis

GB50838-2015 "Technical Code for Urban Utility Tunnel Engineering"

GB/T 51274 "Technical Standard for Monitoring and Alarm System Engineering of Urban Utility Tunnel"

GBZ/T205 "Code of Protection for Occupational Hazards in Confined Space Operation"

GB12358-2006 Gas detectors and alarms for workplace atmosphere - General technical requirements

Sensor Installation:

The Intelligent Ammonia NH3 Gas Sensor is designed to be installed on the sensor socket in a plug-and-play manner. To ensure reliable connection, dedicated sockets should be selected. The sockets should be arranged according to the pin correspondence, installed vertically, and welded firmly. According to user's special requirements, the pin plug-in method can be omitted, and the external lead wire method can be used instead; the wire length generally does not exceed 150mm. In non-explosion-proof places, hot-swapping with power on is allowed. In work sites with explosion-proof requirements, the power supply of the equipment connected to the sensor must be turned off before installation.

Application Market

The Intelligent Ammonia NH3 Gas Sensor is inseparable from fields such as petroleum, petrochemical, metallurgy, chemical industry, electric power, telecommunications, gas, mining, pharmaceuticals, municipal sewage treatment, indoor environment, atmospheric environmental protection, transportation equipment, transportation, tunnel safety, underground parking lots, etc. In recent years, it is mainly used in fields such as environmental data acquisition, gas monitoring, Internet of Things, drones, industrial robots, gridded atmospheric environmental monitors, and micro air quality monitoring stations. Its monitoring effect has been widely recognized by users.

Industry Category Electronic Components & Supplies/Sensors/Gas Sensors
Product Category
Brand: BSA/QT
Spec: BSA/QT-BJ
Manufacturer: 深圳市貝斯安智能科技有限公司
Origin: 114403
Storefront Language: English Chinese
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192