Description
Additional Information

REAL-A Central Air Conditioning Energy-saving Cloud Control Management System

1、System Equipment Control and Management

Due to the characteristics of multi-parameter, nonlinearity, and fluctuating cooling and heating loads in central air conditioning systems, it is easy to cause the system operating conditions to deviate from the efficient operating state, resulting in reduced thermal conversion efficiency of the chiller units. Under the condition of ensuring comfort, in order to improve the energy efficiency of the central air conditioning system, comprehensive energy efficiency tracking control and management of various components such as chiller units and water circulation systems must be implemented.

2、Chiller Units

Based on the collected supply and return water temperatures, pressure, flow rates of the chilled and cooling water circulation systems, and ambient temperature and humidity, the central air conditioning intelligent controller calculates the actual system load and dynamically adjusts the number of operating chiller units and temperature settings. The control modes of chiller units can be divided into two situations.

3、Hot Water Circulation

When ambient temperature, humidity, system process parameters, and the heat load of the air conditioning terminals change, the process parameters of the water circulation system also change accordingly. The central air conditioning intelligent controller optimizes the efficiency of the chiller units based on the cooling load value, provides control strategies, dynamically adjusts the chilled water flow rate through the chilled water pump energy efficiency controller, dynamically adjusts the cooling water flow rate through the cooling water pump energy efficiency controller, dynamically adjusts the hot water flow rate through the hot water pump energy efficiency controller, and adjusts the operating frequency of the cooling tower fans through the cooling tower fan energy efficiency controller to meet the user's heat demand and ensure that the COP of the chiller units remains in an efficient conversion state.

4、Energy Management

On the management computer, centralized control and energy efficiency management of system equipment such as chiller units and related electric regulating valves in the water circulation system are achieved. Through the intelligent metering unit, electricity consumption statistics of the air conditioning system are transmitted via the energy bus to the management computer or other energy statistical management systems, enabling the statistical management of system operating parameters and energy statistical reports.

Specific Models:

REAL-A 1600-J Power Incoming Cabinet

REAL-A2/224.1-K Chiller Unit Feeder Cabinet

REAL-A3/30-2 I Chilled Water Circulation Pump Intelligent Control Cabinet

REAL-A PC System Energy Efficiency Control Main Cabinet

REAL-A3/30-2 Chilled Water Circulation Pump Intelligent Control Cabinet

REAL-A3/15-2 I Hot Water Circulation Pump Intelligent Control Cabinet

REAL-A4/7.5 Cooling Tower Fan Intelligent Control Cabinet

Equipment Product Functions
1. Integrated design of power and control systems, including power distribution, control, frequency conversion, metering, regulation, and a 7-inch human-machine interface.
2. Equipped with international frequency converters capable of suppressing harmonic currents.
3. Built-in intelligent controller (including software).
4. Built-in adaptive optimization model database for cooling water.
5. Controls the start/stop of refrigeration hosts, feedback on operational fault signals, collects supply and return water temperatures for host chilled and cooling water, and collects chilled water flow rates for the host.

V. Main Technical Parameters
Operating ambient temperature: 0°C - 40°C
Relative humidity: ≥90% (at 20°C)
Installation altitude: ≤1000m
Input power voltage: Three-phase AC 380V ±38V / Single-phase AC 220V
Input power frequency: 50Hz
Output power: Three-phase AC 0V - 380V
Output frequency: 0Hz - 50Hz
Control cabinet protection rating: IP

Xi'an Yachuan Power Technology Co., Ltd.
Manager Liu
Phone/WeChat: 13572979371 (一三五七二九七九三七一)
Welcome to call for discussions!

Industry Category Machinery & Equipment/Compression & Separation Equipment/Oxygen Generation Equipment
Product Category
Brand:
Spec: REAL- A3/15-2
Stock:
Origin: China / Shaanxi / Xianshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 义马市| 林西县| 泽州县| 德庆县| 武川县| 莱阳市| 贵定县| 博爱县| 光山县| 青龙| 内黄县| 廉江市| 双流县| 保靖县| 汉中市| 沙雅县| 澜沧| 当涂县| 南乐县| 延吉市| 绥宁县| 德清县| 溧水县| 满城县| 安宁市| 钟山县| 金堂县| 东平县| 岱山县| 怀化市| 福州市| 东辽县| 江川县| 叙永县| 洪湖市| 准格尔旗| 介休市| 香格里拉县| 柘城县| 黑龙江省| 丹凤县|