尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Dissolved Oxygen Electrode - China Supplier
China Dissolved Oxygen Electrode - China Supplier

Dissolved Oxygen Electrode

Price:Negotiable
Industry Category: Instruments & Meters/Water Quality Testing Instruments/Water Quality Testing Instruments
Product Category:
Brand:
Spec:


Contact Info
  • Add:宜興市高塍鎮(zhèn)江南路126號(hào), Zip: 214214
  • Contact: 余麗蘭
  • Tel:0510-87838003
  • Email:wxzjhb@163.com

Other Products

Description
Additional Information

Introduction to Dissolved Oxygen Electrode Utilizing a polarographic electrode, the anode is made of Ag/AgCl and the cathode of platinum (Pt), with a special electrolyte solution filled between them. The electrode is encapsulated by a silicone rubber permeable membrane. During measurement, a polarization voltage of 675 mV is applied between the electrodes. Oxygen permeates through the membrane and is consumed at the cathode, while an equivalent amount of oxygen is generated at the anode. This dynamic process continues until the oxygen partial pressures on both sides reach equilibrium. At this point, the current between the electrodes is proportional to the oxygen partial pressure. The secondary meter detects this current and, through a series of conversions, obtains the oxygen concentration and content. Simultaneously, an NTC (Negative Temperature Coefficient thermistor) detects the temperature of the measured liquid. The secondary meter samples the data and performs temperature compensation, converting the oxygen concentration or content to values at 25°C. Cathode reaction: O? + 2H?O + 4e? → 4OH? Anode reaction: 4Ag + 4Cl? → 4AgCl + 4e? Applications Dissolved oxygen electrodes can be used to monitor processes where oxygen content affects reaction speed, process efficiency, or the environment, such as in aquaculture, bioreactions, environmental testing (lakes, streams, oceans), water/wastewater treatment, and wine production. The T401ppm dissolved oxygen electrode offers high stability and reliability, suitable for use in harsh environments with minimal maintenance. Troubleshooting When using polarographic electrodes, preheat for at least 15–30 minutes before calibration or measurement. To ensure no bubbles are present in the electrolyte of the membrane, the ASI membrane cap is designed to expel all air from the liquid chamber when installing the membrane head. No bubbles should remain on the membrane surface, as they may be misinterpreted as oxygen-saturated samples. Even when using instruments with automatic temperature compensation, calibrate the electrode at a temperature close to that of the sample solution. Calibrate the electrode in air, using air as the 100% saturated dissolved oxygen reference point. Since the electrode consumes oxygen, the oxygen concentration at the probe surface momentarily decreases. Therefore, it is essential to stir the solution during measurement. Replace the membrane if it is damaged. Technical Parameters: Measurement range: 0–20 mg/L (ppm), 0–200% Operating temperature: 0–130°C Temperature compensation range: 0–130°C Measurement principle: Amperometric sensor Membrane thickness: 50 μm Electrode material: UPVC or 316L Sensing material: POM outer tube, silver tube, gold wire with temperature compensation function Response time: 90% in 60 seconds (upscale, at 20°C) Polarization time: 2 hours Minimum flow rate: 2.5 cm/s Cable length: Standard 10 m Installation method: 3/4-inch pipe thread installation Standard configuration: One electrode, two spare membrane heads, one bottle of specialized electrolyte solution.

Industry Category Instruments & Meters/Water Quality Testing Instruments/Water Quality Testing Instruments
Product Category
Brand:
Spec:
Stock:
Origin:
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 翼城县| 家居| 玉林市| 吕梁市| 衡南县| 英山县| 丹江口市| 武胜县| 桐柏县| 常州市| 锡林浩特市| 东辽县| 寻甸| 普安县| 永川市| 红安县| 涞水县| 彭山县| 鸡西市| 文山县| 资兴市| 区。| 江孜县| 宜丰县| 北川| 湖南省| 潼关县| 邳州市| 达州市| 长子县| 纳雍县| 博野县| 锡林浩特市| 屯门区| 唐河县| 平武县| 伊通| 淳安县| 三门峡市| 富民县| 绿春县|