尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Cable Online Fault Warning and Location System WRS-CBS11X Series - Volsun Electric - China Supplier
China Cable Online Fault Warning and Location System WRS-CBS11X Series - Volsun Electric - China Supplier China Cable Online Fault Warning and Location System WRS-CBS11X Series - Volsun Electric - China Supplier China Cable Online Fault Warning and Location System WRS-CBS11X Series - Volsun Electric - China Supplier

Cable Online Fault Warning and Location System WRS-CBS11X Series - Volsun Electric

Price:Negotiable
Industry Category: Electrical Equipment & Supplies/Power Distribution & Transmission/Other Power Distribution Equipment
Product Category:
Brand: 沃倫森
Spec: WRS-CBS11X


Contact Info
  • Add:臨平區(qū)塘棲鎮(zhèn)土山壩路6號(hào)3幢, Zip:
  • Contact: 鐘女士
  • Tel:0573-82829261
  • Email:wolunsun@163.com

Other Products

Description
Additional Information

The WRS-CBS11X series cable online fault warning and positioning system developed by our company conducts real-time online monitoring of cable operating conditions, collects transient traveling waves and steady-state components during cable operation, analyzes and processes them to predict cable operating conditions, provides alarm and fault diagnosis information for faulty cables, monitors the insulation status of cables, issues warnings for permanent faults, and achieves fault location and fault line selection. It provides a reliable basis for condition-based maintenance, making it possible to transition cable lines from traditional periodic maintenance to condition-based maintenance. This not only reduces planned power outage time but also minimizes the damage caused by high-voltage preventive tests on cables.
Features:

Fault Location: The system utilizes voltage traveling wave and current traveling wave fault location technology to achieve fault point location, with a fault location accuracy of up to 2.12m.
Fault Line Selection: The system monitors the operating status of each cable in real time and performs cable loop selection for main insulation faults.
System Cloud Service: Provides sufficient user space for each user, allowing access to on-site system monitoring via a browser anytime and anywhere. Historical data is permanently stored for easy review.
Local Functionality: The system backend is installed in the main station, configured with a primary system diagram, enabling fault warning, line selection, and location. The system diagram flashes for faulty lines, with pop-up alarms, sound alerts, and WeChat mini-program notifications.
Electronic Duty: Enables unmanned operation, with alarm information and working status pushed to relevant personnel via WeChat mini-program.
Remote Technical Support: 7*24-hour remote service, providing auxiliary analysis of fault waveforms and remote system program upgrades.
Historical Storage: Real-time information storage, allowing historical data queries and more.
Warning Methods: Yellow Warning: When an abnormality occurs in the cable, the device immediately captures the waveform and displays a yellow warning. This indicates arcing in the phase cable, requiring close attention. The discharge amount for instantaneous arcing is approximately 3,000 microcoulombs.
Orange Warning: When dozens of waveforms are triggered daily, the system issues an orange warning. Users should arrange maintenance as soon as possible. The discharge amount for instantaneous arcing is approximately 3,000–5,000 microcoulombs.
Red Warning: Trigger frequency increases rapidly, and the cable is likely to fail soon (within 24 hours). The system enters a red warning state, and users should immediately conduct a power outage for maintenance. The discharge amount for instantaneous arcing is approximately 5,000–8,000 microcoulombs. Additionally, if the cable suffers irreversible external damage (e.g., mechanical damage such as being cut), the system directly reports a red warning for the faulty line.

Technical Parameters:
Current Signal Sampling Frequency: 50MHz, 8 channels
Voltage Signal Sampling Frequency: 200kHz × 5 channels
System Positioning Accuracy: 2.12m
Fault Line Selection Accuracy: ≥99%
Single-End Fault Location Range for Current: ≤5km
Test Blind Zone: ≤5m
Cloud Communication Method: Wireless 4G communication
System Device Communication Method: RJ45
System Expansion: Supports up to 253 monitoring units in a network
System Power Supply: AC/DC 220V ±20%
System Operating Temperature: -25°C to +70°C
System Online Safe Operation: >80,000 hours

(The table lists only some specifications; other capacities can be customized as needed.)


Keywords: Cable Fault Location System, Cable Warning System

Industry Category Electrical Equipment & Supplies/Power Distribution & Transmission/Other Power Distribution Equipment
Product Category
Brand: 沃倫森
Spec: WRS-CBS11X
Stock:
Origin: China / Zhejiang / Hangzhoushi
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 塔城市| 剑河县| 波密县| 桦川县| 宜良县| 呼玛县| 隆尧县| 平南县| 玛纳斯县| 林周县| 通江县| 开原市| 绥德县| 钟祥市| 石门县| 措美县| 福贡县| 尉犁县| 阳泉市| 岳普湖县| 武威市| 陇西县| 隆德县| 潮州市| 乃东县| 吉首市| 唐山市| 崇文区| 清远市| 曲周县| 绥江县| 广饶县| 城固县| 泉州市| 西乌| 陈巴尔虎旗| 新竹县| 乃东县| 梨树县| 平舆县| 申扎县|