In public building energy consumption, central air conditioning accounts for approximately 60% of total energy usage, exceeding the combined energy consumption of lighting, elevators, and office equipment. Therefore, the focus of building energy conservation and emission reduction lies in the central air conditioning system.


Summary of Central Air Conditioning System Issues

lNo Remote Centralized Control

1.After entering a room, personnel manually set excessively low/high temperatures for rapid cooling/heating, failing to restore normal settings once the temperature is reached, resulting in significant energy waste;

2.Over-pursuit of low/high temperatures leads to prolonged high-load operation of air conditioners, poor comfort, severe energy waste, and reduced lifespan of the units;

3.Air conditioners remain operational during off-hours, holidays, and other unoccupied periods, wasting energy.

lNo Real-Time Data Monitoring

1.Inability to visually monitor air conditioner operation and data; remote real-time fault detection is unavailable, increasing the workload of inspection personnel;

2.Long data collection intervals may lead to omissions; network or program abnormalities in monitoring computers can cause billing issues.

lNo Data Analysis and Management

1.Management personnel cannot perform statistics, analysis, or management of energy data and consumption indicators for central air conditioning;

2.No alerts for abnormal electricity costs; inability to promptly control unreasonable increases in air conditioning electricity expenses.

Therefore, implementing energy-saving renovations for central air conditioning systems enables centralized control and real-time monitoring of operation status, preventing overcooling or overheating. This improves indoor comfort while reducing energy waste, lowers operational load and failure rates of air conditioners, enhances energy efficiency and operational management levels, visualizes centralized management and utilization rates, and reduces building operational electricity costs.

Multi-Split Intelligent Centralized Control and Billing System

Solution Overview

The Multi-Split Intelligent Centralized Control and Billing System is the latest generation of centralized management systems for variable refrigerant flow (VRF) multi-split air conditioners. One management computer can connect to multiple protocol-compatible air conditioning modules, enabling centralized management of indoor units. This system connects all air conditioning units to a computer for automated control, offering powerful functionality, simple operation, and remote control capabilities.
The centralized control panel for multi-split air conditioners allows mode and power control of all units with a single remote, simplifying operation. It also supports grouping and settings adjustments at any time, making it an ideal choice for property management.

System Bus Architecture Logic


System Functions

1. Power on/off control

2. Operation mode setting (cooling, heating, dehumidification, fan)

3. Temperature setting with upper and lower limits

4. Fan speed setting (high, medium, low)

5. On-site remote control lock (full or partial locking of settings such as power, mode, temperature, fan speed)

6. Scheduled automatic operation for different users based on customized timetables

View the following information for each indoor unit:

1. Real-time status (power, operation mode, fan speed, temperature setting)

2. Power on/off history

3. Alarm and fault history

4. Cumulative operation time

5. Electricity cost inquiry

6. Energy consumption statistics - electricity cost inquiry

7. Energy consumption statistics - daily usage details

8. Energy consumption statistics - standby power allocation

9. Energy consumption statistics - meter reading records

Air Conditioning Management Interface

The air conditioning management page allows selection of one or multiple cooling systems within the air conditioning system for individual or centralized management. Through management buttons, users can control power, set parameters, and view the number, address, and status of connected indoor units.


Air conditioning zone selection, indoor unit selection interface

The interface includes mode lock, function buttons identical to those on indoor units, and speed/temperature limits.




Industry Category Others
Product Category
Brand: 拓森
Spec: 多聯(lián)機(jī)
Stock: 100
Manufacturer:
Origin: China / Fujian / Xiamenshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 开鲁县| 南安市| 荔波县| 老河口市| 镇江市| 休宁县| 兴文县| 深州市| 卢氏县| 保靖县| 平邑县| 扶沟县| 安庆市| 芮城县| 于田县| 大关县| 深圳市| 秭归县| 四平市| 左云县| 白玉县| 浦县| 商都县| 灵武市| 商丘市| 东港市| 栾川县| 九寨沟县| 柳河县| 息烽县| 新邵县| 桑植县| 万安县| 深州市| 贡山| 庄河市| 农安县| 台中县| 德阳市| 高平市| 大新县|