尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Circulating Water Cooling and Heating Constant Temperature System - China Supplier
China Circulating Water Cooling and Heating Constant Temperature System - China Supplier China Circulating Water Cooling and Heating Constant Temperature System - China Supplier China Circulating Water Cooling and Heating Constant Temperature System - China Supplier China Circulating Water Cooling and Heating Constant Temperature System - China Supplier China Circulating Water Cooling and Heating Constant Temperature System - China Supplier

Circulating Water Cooling and Heating Constant Temperature System

Price:Negotiable
Industry Category: Machinery & Equipment/Compression & Separation Equipment/Screw Compressors
Product Category:
Brand: Ninewells
Spec: JRW-30QA


Contact Info
  • Add:深圳市龍崗區(qū)坪地街道年豐社區(qū)橫嶺中路1號(hào)第七棟, Zip: 518116
  • Contact: 李大紅先生
  • Tel:0755-29084657
  • Email:szkawai@yeah.net

Other Products

Description
Additional Information

Circulating Water Cooling and Heating Constant Temperature System

Introduction

Water Constant Temperature - Circulating Water Cooling and Heating Constant Temperature System. The heating method utilizes heat from the air to warm the water, eliminating the need for additional heating elements. In this era of environmental conservation and energy efficiency, this unit fully meets market demands..

Unit Cooling Principle

The compressor operates, converting low-temperature, low-pressure gaseous refrigerant into high-temperature, high-pressure gaseous refrigerant, which enters the condenser. Part of the heat from the refrigerant inside the condenser is expelled by external cooling water or cooling fans. The refrigerant releases heat and liquefies into a high-temperature, high-pressure liquid, which then flows through a dryer filter for drying and filtration. It then enters the expansion valve for throttling (a rapid cooling process) and pressure reduction. The refrigerant liquefies into a low-temperature, low-pressure liquid and enters the evaporator for heat exchange. The low-temperature, low-pressure liquid refrigerant absorbs heat from the surrounding medium (water, oil) outside the evaporator. During the heat absorption process, the refrigerant temperature remains constant while its volume changes. The low-pressure hydraulic refrigerant, after absorbing heat, vaporizes into a low-temperature, low-pressure gaseous refrigerant and enters the compressor. After compression by the compressor, it becomes a high-temperature, high-pressure gas and enters the condenser, thus completing the entire refrigeration cycle.

Unit Heating Principle

Based on the refrigeration principle, the compressor operates, converting low-temperature, low-pressure gaseous refrigerant into high-temperature, high-pressure gas, which passes through a four-way valve and a liquid storage tank. The refrigerant enters the condenser, where the heat inside is utilized to heat the water tank, with heated water reaching up to 90 degrees Celsius. The refrigerant releases heat and liquefies into a high-temperature, high-pressure liquid, which then flows through a dryer filter for drying and filtration. It then enters the expansion valve for throttling (a rapid cooling process) and pressure reduction. The refrigerant liquefies into a low-temperature, low-pressure liquid and enters the evaporator for heat exchange. The low-temperature, low-pressure liquid refrigerant absorbs heat from the surrounding medium (water, oil) outside the evaporator. During the heat absorption process, the refrigerant temperature remains constant while its volume changes. The low-pressure hydraulic refrigerant, after absorbing heat, vaporizes into a low-temperature, low-pressure gaseous refrigerant and enters the compressor. After compression by the compressor, it becomes a high-temperature, high-pressure gas and enters the condenser, thus completing the entire heating cycle.

Features

The Circulating Water Cooling and Heating Constant Temperature System has eight major protection devices:1. Phase loss and reverse phase protection device; 2. Motor overload protection device; 3. High and low pressure protection device; 4. Automatic water shortage alarm device; 5. Low temperature and anti-freezing protection device; 6. Coil overheating protection device; 7. Insufficient water flow protection device; 8. Fully automatic temperature control system

Unit Performance

The unit is entirely manufactured using original components supplied by reputable brands recognized in the market, ensuring stable performance and continuous operation of this series.

Control System

1. Control components, microcomputer boards, single modules, PLCs, etc., use brands such as LG, Bopu, Siemens, Schneider, Mitsubishi, all of which are market-recognized brands.

2. To enhance the stability and safety of the Circulating Water Cooling and Heating Constant Temperature System during use, the EU quality management system certification has been actively implemented in the production process. Strict control over product quality is maintained in supplier selection, and load specifications are rigorously standardized. The unit's performance includes additional protection devices such as phase loss and reverse phase protection, motor overload protection, high and low pressure protection, automatic water shortage alarm, low temperature and anti-freezing protection.

After-Sales Service

1.One-year free warranty, lifetime maintenance (excluding human factors, consumables, and force majeure),

2.Upon receiving written equipment repair notification from the customer, response and on-site repair within 36 hours within Guangdong Province, and 72 hours outside Guangdong Province.

3.After the warranty period, a separate service agreement can be arranged to ensure effective protection during the customer's production process.

4.During the warranty period, if equipment failure is caused by product quality (excluding human factors), all costs will be borne by our company.

5.Outside the warranty period, costs incurred for equipment maintenance will be charged based on actual expenses.

Unit Technical ParametersAir energy water refrigeration heating machine set Technical Parameters

<極端>

7482

<極端的>

120000

Model
Model

Refrigeration Capacity
Refrigerati
ng capacity

Heating Capacity

Compressor
Compressor

Evaporator
Evaporator

Condenser
Condenser

Water Pump
water pump

Dimensions

Shape dimension

kcal/h

kw

kw

kw

hp

L

inch

m3/h

m3/h

kw

mpa

cm

JRW-01QA

2494

2.9

3.1

0.75

1

18

3∕4"

1.2

1000

0.37

0.18

75×62×90

JRW-02QA

4988

5.8

6.2

1.5

2

40

3∕4"

1.2

2000

0.37

0.18

88×65×105

JRW-03QA

8.7

9.3

2.2

3

45

3∕4"

1.8

3000

0.37

0.18

104×67×110

JRW-04QA

9976

11.6

12.4

3

4

60

3∕4"

2.6

4000

0.37

0.18

120×60×115

JRW-05QA

12470

14.5

15.5

3.75

5

70

1

3

5000

0.75

極端的

130×75×120

JRW-06QA

14964

17.4

18.6

4.5

6

90

1

3.6

6000

0.75

0.18

135×80×135

JRW-08QA

19552

23.2

24.8

6

8

140

2"

5

8000

0.75

0.18

145×90×140

JRW-10QA

24940

29

31

7.5

10

160

2"

6

10000

1.5

0.18

155×95×150

JRW-12QA

29928

34.8

37.2

9

12

170

2"

7.5

12000

1.5

0.18

160×100×160

JRW-15QA

37410

<極端的>43.5

46.5

11

15

200

2"

9

15000

1.5

0.18

170×110×175

JRW-20QA

49880

58

62

15

20

300

2"

12

20000

2.2

0.18

185×120×180

JRW-25QA

59856

69.6

77.5

18

25

300

2.5"

15

25000

2.2

0.18

190×125×185

JRW-30QA

74820

87

93

22.5

30

450

2.5"

18

30000

3

0.18

210×140×200

JRW-40QA

99760

116

124

30

40

600

2.5"

25

40000

3.75

0.18

220×150×210

JRW-50QA

124700

145

155

37.5

極端的>50

700

3"

32

50000

3.75

0.18

240×160×220

JRW-60QA

149640

174

186

45

60

800

3"

40

60000

3.75

0.18

270×170×240

JRW-40QAS

103200

120

126

30

40

-

2.5

26

40000

-

200×65×160

JRW-50QAS

129000

150

157.5

37.5

50

-

3"

30

50000

-

-

200×極端的>65×165

JRW-60QAS

154800

180

189

45

60

-

4"

36

60000

-

-

250×65×165

JRW-70QAS

180600

210

220.5

52.5

70

-

4"

42

70000

-

-

255×65×165

JRW-80QAS

206400

240

252

60

80

-

4"

48

80000

-

-

280×65×180

JRW-100QAS

258000

300

315

75

100

-

4"

62

100000

-

-

320×65×180

JRW-120QAS

309600

360

378

90

120

-

4"

74

-

-

350×80×180

JRW-140QAS

361200

420

441

105

140

-

4.5"

86

140000

-

-

360×80×190

JRW-150QAS

399900

456

472.5

112

150

-

極端的>4.5"

92

150000

-

-

360×80×180

JRW-160QAS

426560

496

504

120

160

-

4.5"

106

160000

-

-

390×110×160

JRW-180QAS

479880

558

567

135

180

-

4.5"

112

180000

-

-

410×110×160

JRW-200QAS

533200

620

630

150

200

-

4.極端的>5"

118

200000

-

-

410×140×160

Note: 1. Refrigeration compressor: Supports a maximum temperature of 45°C, uses refrigerant R22. Refrigeration compressor: Support highest temperature  45 ℃、Refrigerant R22 for use.

2. Screw unit energy automatic control is 75%-50%-25%. Screw water chillers energy automatic control for 75%-50%-25% 。

3. Evaporation temperature inlet water 12°C, evaporation temperature outlet water 7°C. Condensation temperature inlet water 30°C, condensation temperature outlet water 35°C. Evaporation temperature into the water 12 ℃、Evaporation temperature water 7 ℃、Cooling water temperature into 30 、Cooling water temperature for 35。

4. The above parameters are subject to change without prior notice. The above parameters are subject to change without prior notice.

Industry Category Machinery & Equipment/Compression & Separation Equipment/Screw Compressors
Product Category
Brand: Ninewells
Spec: JRW-30QA
Stock: 0
Origin: China / Guangdong / Shenshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192