Nanhong Electric NRT-511 Digital Transformer Differential Protection Device

I. Overview
1.1 Scope of Application
The NRT-511 digital transformer differential protection device is suitable for transformer protection in substations with voltage levels of 110kV and below, serving as the main protection for three-winding transformers.
1.2 Device Function Configuration
1.2.1 Differential Instantaneous Trip Protection
Operates quickly to trip during severe internal faults in the transformer.
The protection operation criterion is: Id > Isd × Ie
Where: Id: differential current, Isd: differential instantaneous trip setting value,
Ie is the rated current on the high-voltage side.
If any phase of the three-phase differential current satisfies Id > Isd × Ie, the output action is triggered.
1.2.2 Percentage Restraint Differential Protection
Adopts the conventional percentage differential protection principle, reliably avoiding unbalanced differential current during external faults. Its operation equations are as follows:
Id > Iqd × Ie (before the breakpoint)
Id > Iqd × Ie + Kbl (Ir - Ieg × Ie) (after the breakpoint)
Where: Id: differential current; Ie: rated current on the high-voltage side; Ir: restraint current;
Kbl: percentage restraint coefficient; Iqd: differential starting setting value; Ieg: breakpoint current setting value.
For details, refer to Table 1 on page 2 of this manual.
1.2.3 Calculation Methods for Differential Current and Restraint Current
Id = | IH + IM + IL |
Ir = max{|IH|, |IM|, |IL|}
Where IH, IM, IL are the currents on the high-voltage, medium-voltage, and low-voltage sides of the transformer, respectively.

Industry Category Electrical Equipment & Supplies/Low Voltage Electrical/Reactors
Product Category
Brand: 南宏電力
Spec: NRT-511
Stock: 100
Manufacturer:
Origin: China / Hubei / Yichangshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 绩溪县| 永州市| 新泰市| 息烽县| 静宁县| 交城县| 托克逊县| 石城县| 鹤峰县| 三门峡市| 吉首市| 泗水县| 鄂托克前旗| 子长县| 遵义县| 华容县| 蛟河市| 台南市| 大埔县| 江源县| 洛扎县| 沾化县| 徐水县| 沅江市| 普兰店市| 龙陵县| 清镇市| 山东省| 额敏县| 孝感市| 嘉峪关市| 宜黄县| 拉萨市| 德州市| 贵德县| 肇东市| 浦县| 湘西| 东阿县| 凤山县| 伊宁县|