尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China XKYFL-600B Fully Automatic Fluorine and Chlorine Determinator Coal Testing Instrument Coal Quality Analyzer - China Supplier
China XKYFL-600B Fully Automatic Fluorine and Chlorine Determinator Coal Testing Instrument Coal Quality Analyzer - China Supplier China XKYFL-600B Fully Automatic Fluorine and Chlorine Determinator Coal Testing Instrument Coal Quality Analyzer - China Supplier

XKYFL-600B Fully Automatic Fluorine and Chlorine Determinator Coal Testing Instrument Coal Quality Analyzer

Price:面議
Industry Category: Instruments & Meters/Specialized Instruments/Other Specialized Instruments
Product Category:
Brand: 欣科源
Spec: XKYFL-600B


Contact Info
  • Add:湖南省長沙縣安沙鎮(zhèn)安沙社區(qū)護豐組, Zip:
  • Contact: 王經(jīng)理
  • Tel:15573135383
  • Email:csxkyyq@163.com

Other Products

Description
Additional Information

Changsha Xinkeyuan 155 7313 5383 Manager Wang

Scope of Application

Suitable for the determination of fluorine and chlorine content in solid or liquid combustible materials such as coal, solid waste, coke, petroleum, ores, and biomass fuels. Widely applicable in industries including coal, power, metallurgy, chemical, building materials, cement, papermaking, commodity inspection, quality inspection, environmental protection, as well as fields like geological exploration, solid waste treatment, scientific research institutions, and universities.

Performance Features

High-temperature hydrolysis and potentiometric determination can operate simultaneously and independently. Technical parameters exceed national standard requirements, with a high degree of automation, achieving a perfect balance between testing efficiency and ease of use.

The high-temperature hydrolysis device features a dual-channel design, allowing two analytical samples to be processed at once. The entire high-temperature hydrolysis process is automated, including temperature control, sample feeding, steam generation, condensation, and condensate collection, enabling truly unattended operation by lab technicians. By pre-adjusting the power of the steam generator, the collected condensate in both pipelines meets national standard requirements. At the end of the test, the system alerts the user and automatically switches the condensate pipeline to waste discharge mode to prevent overfilling of the condensate volume used for sample measurement.

Detail Image One

Equipped with a one-click airtightness detection device for convenient pre-test leakage checks.

The fluoride titrator supports both automatic potentiometric titration and manual titration of standard solutions. After standard curve measurement, it automatically generates: E0, slope, and regression coefficient. According to national standards, the ΔE during sample titration should be controlled between 20 mV and 40 mV, which is difficult to achieve manually. The automatic fluoride ion titrator uses ANLS technology to programmatically control and measure the dosage of fluoride standard solution, keeping ΔE within 25–35 mV, easily meeting national standards. The instrument automatically calculates results and supports data storage and printing.

The chloride titrator automatically controls reagent dosage via program, completes titration, generates tables, plots differential curves, and records the volume of standard solution used at the endpoint potential. The endpoint potential is automatically saved after parallel determinations. During sample testing, the titration endpoint can be easily controlled within ±1 mV of the endpoint potential. The instrument automatically calculates results and supports data storage and printing.

The titrator offers both standalone operation and computer-connected operation modes to accommodate different user preferences.

Compliant Standards

GB/T 3558-2014 "Determination of Fluorine in Coal"

GB/T 4633-2014 "Determination of Chlorine in Coal"

GB/T 30729-2014 "Determination of Chlorine in Solid Biofuels"

Technical Parameters

Number of Samples: Dual-pipeline design, capable of decomposing 2 samples simultaneously.

Sample Mass: 0.5g

Testing Range:

Fluorine: 10 ppm–2000 ppm (10–2000 μg/g)

Chlorine: 30 ppm–4000 ppm (0.003–0.400%)

Testing Time:

High-Temperature Hydrolysis Time: 30 min (as specified by national standard)

Solution Analysis Time: Fluorine <3 min/sample; Chlorine <3 min/sample

Repeatability: Meets precision requirements of national standards

Temperature Control Accuracy: 1100±2°C

Power Supply: AC220V, 50Hz

Dimensions:

High-Temperature Hydrolysis Furnace: (Floor-standing)

1350×600×1130 mm

Titrator: (Benchtop, connectable to computer)

350×300×350 mm

Industry Category Instruments & Meters/Specialized Instruments/Other Specialized Instruments
Product Category
Brand: 欣科源
Spec: XKYFL-600B
Stock: 100
Manufacturer:
Origin: China / Hunan / Changshashi
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 泾阳县| 武鸣县| 巴里| 余庆县| 阳新县| 华宁县| 庆元县| 临沭县| 桂阳县| 汕尾市| 桂阳县| 长岛县| 通榆县| 元江| 皮山县| 阳曲县| 大厂| 建始县| 建湖县| 昌图县| 北海市| 禄劝| 甘南县| 津南区| 卢氏县| 杭锦后旗| 泰顺县| 榆中县| 青浦区| 兰溪市| 瓮安县| 安新县| 浑源县| 濮阳县| 梓潼县| 青河县| 永吉县| 苏州市| 乌海市| 长海县| 清原|