尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China 2X Series Rotary Vane Vacuum Pump - Rotary Vane Vacuum Pump - Vacuum Pump - Vane Pump - China Supplier
China 2X Series Rotary Vane Vacuum Pump - Rotary Vane Vacuum Pump - Vacuum Pump - Vane Pump - China Supplier

2X Series Rotary Vane Vacuum Pump - Rotary Vane Vacuum Pump - Vacuum Pump - Vane Pump

Price:Negotiable
Industry Category: Machinery & Equipment/Compression & Separation Equipment/Oxygen Generation Equipment
Product Category:
Brand:
Spec:


Contact Info
  • Add:山東省淄博市博山區(qū)白塔工業(yè)園, Zip: 255200
  • Contact: 吳經(jīng)理
  • Tel:0533-4686966
  • Email:304026142@qq.com

Other Products

Description
Additional Information

Working Principle
The rotary vane pump mainly consists of the pump body, rotor, vanes, end cover, spring, etc. A rotor is eccentrically installed inside the pump chamber, with its outer circle tangent to the inner surface of the pump chamber (with a very small gap between them). Two vanes with springs are placed in the rotor slots, dividing the stator into two working chambers (high and low stage working chambers). During rotation, centrifugal force and spring tension keep the top of the vanes in contact with the inner wall of the pump chamber. The rotation of the rotor drives the vanes to slide along the inner wall of the pump chamber, causing the volume of the high-stage working chamber to periodically expand for suction, and the volume of the low-stage working chamber to periodically shrink to compress the gas. The gas and oil pressure push open the exhaust valve to discharge the gas, thereby achieving vacuum. When the suction pressure is high (e.g., starting from atmospheric pressure), the gas is compressed in the high-stage chamber, and the pressure increases rapidly. Part of the compressed gas is directly discharged through the auxiliary exhaust valve, while the remaining gas is compressed and enters the low-stage chamber through the interstage passage in the middle wall. After further compression, it is discharged from the low-stage exhaust valve. In this case, both the high and low-stage chambers discharge simultaneously. When the suction pressure is low (e.g., after the pump has been running for some time), gas enters the high-stage chamber through the suction port. The pressure generated by compression in the high-stage chamber is insufficient to push open the auxiliary exhaust valve, so the gas directly enters the low-stage working chamber through the interstage passage. After further compression, it is discharged from the low-stage exhaust valve.

Application Range
It can be widely used in processes such as vacuum smelting, vacuum welding, vacuum impregnation, vacuum coating, vacuum heat treatment, vacuum drying, and vacuum packaging in industries like refrigerators, air conditioners, light bulbs, fluorescent lamps, vacuum flask production, electronics, metallurgy, pharmaceuticals, chemicals, oil filters, printing machinery, and packaging machines. It can serve as a backing pump for diffusion pumps, Roots pumps, molecular pumps, etc., and is used for supporting electronic instruments, medical instruments, and experimental research applications.

Performance Curve

2X Series

Precautions
1. The pump can operate continuously for extended periods under environmental temperatures of 5–40°C and an inlet pressure of less than 1330 Pa.
2. If equipped with a gas ballast device, the pump can also remove a certain amount of condensable gas. However, it is not suitable for removing gases with excessively high oxygen content, toxic gases, explosive gases, gases corrosive to metals, gases that react chemically with pump oil, or gases containing particulate dust. It also cannot be used as a transfer pump.
3. The continuous operation time of the pump under inlet pressures ranging from atmospheric pressure to 6000 Pa should not exceed 3 minutes to avoid oil spraying or poor lubrication, which could damage the pump.
4. The oil level should be at the center of the oil gauge. A high oil level may cause oil spraying, while a low oil level may result in poor lubrication. The oil level should be checked while the pump is running. It is best to change the vacuum pump oil while the pump is running, as this facilitates thorough replacement and helps discharge impurities from the pump chamber as much as possible.

Performance and Specifications

Performance Functions\Model2X-4A2X-8A2X-82X-152X-30A2X-70A
Pumping Speed (L/S)488153070
Ultimate Pressure (≤Pa)≤6x10-2
Motor Power (kW)0.551.11.12.235.5
Temperature Rise (°C)≤40°C
Noise dB(A) LW≤72≤75≤75≤80≤82≤86
Inlet Diameter (mm)Φ25Φ25Φ40Φ40Φ65Φ80
Rotational Speed (rpm)450550320320450420
Injection Amount of Oil (L)0.70.922.824.2
Size (cm)55x34x4055x43x4279x43x5479x53x5478x50x5691x65x70
Weight (Kg)5070130190235420


Installation Dimensions Diagram

ModelABCDE4-Ф
2X-4A400340200550480Ф10
2X-8A420430200550480Ф10


2X-8, 15

ModelABCDEF
2X-8431384260104215274
2X-15531484356110261324

Industry Category Machinery & Equipment/Compression & Separation Equipment/Oxygen Generation Equipment
Product Category
Brand:
Spec:
Stock:
Origin:
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.