尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Explosion-proof Phosphine Gas Alarm - China Supplier
China Explosion-proof Phosphine Gas Alarm - China Supplier China Explosion-proof Phosphine Gas Alarm - China Supplier China Explosion-proof Phosphine Gas Alarm - China Supplier China Explosion-proof Phosphine Gas Alarm - China Supplier China Explosion-proof Phosphine Gas Alarm - China Supplier

Explosion-proof Phosphine Gas Alarm

Price:¥1600 /個(gè)
Industry Category: Instruments & Meters/Analytical Instruments/Other Analytical Instruments
Product Category:
Brand: 貝斯安
Spec: BSA/QT-BJ


Contact Info
  • Add:深圳市龍崗區(qū)坂田街道新雪社區(qū)上雪路4號(hào)熙駿大廈四層405, Zip:
  • Contact: 丁工
  • Tel:18018762641
  • Email:2183550010@qq.com

Other Products

Description
Additional Information


Introduction

A gas alarm is an explosion-proof safety device capable of performing rapid, reliable, and stable continuous detection of gas concentrations in industrial production. When the detected gas concentration reaches the preset alarm value, the alarm triggers and drives external devices to alert on-site personnel to take necessary protective measures, thereby preventing combustion accidents caused by gases.

Working principle of the gas alarm: The alarm is powered and operational when installed on-site. When a gas leak occurs, the sensor converts the detected leakage amount into a corresponding voltage signal output. This voltage signal is processed by the alarm, then the data is uploaded and displayed on the screen. When the concentration reaches the set action value, the alarm triggers and drives external devices.

A gas alarm is a fixed instrument that continuously detects the concentration of oxygen or toxic, harmful, flammable, and explosive gases in the working environment.

The gas alarm uses a diffusion method to convert the gas concentration signal at the monitoring point into an electrical signal in real time. This signal is amplified and then processed by the CPU through AD sampling, temperature compensation, and intelligent calculation. If the measured value exceeds the set alarm concentration, an alarm signal is triggered.

The gas alarm features a dual-chamber design and uses specialized imported sensors. The sensors are modular in design, making calibration and adjustment more convenient. With superior performance, high stability, multiple signal outputs, and easy installation and maintenance, it meets the high reliability requirements of industrial sites.

Features

Ingenious structural design for extremely simple installation;

Freely set upper and lower alarm points across the full range;

Explosion-proof design, suitable for Zone 1 and Zone 2 hazardous areas in factory conditions;

Optional LCD concentration display for real-time on-site concentration monitoring;

Optional dedicated explosion-proof audible and visual alarm for on-site sound and light alerts;

Meets any range requirement between 1-99999 and all gas detection needs;

Two sets of normally open passive contact outputs for controlling fans or AC contactors of solenoid valves;

Elegant power supply design with pure SMT component assembly ensures stable product performance;

Sensors use imported gas-sensitive components, offering high precision, long lifespan, minimal zero drift, fast response time, continuous long-term operation, compact size, easy operation, and strong anti-poisoning performance;

Allows adjustment of alarm points, zero points, and target point calibration via the controller without opening the cover;

Suitable for detecting dozens of gases and displaying gas names; gas unit names include ppm, LEL%, VOL%, and mg/m3;

International standard (4–20)mA signal can be directly connected to the factory DCS system; RS485 digital signal can connect to the factory host computer;


Accuracy

±2%FS (High Precision Type), ±5%FS (Standard Type)

Weight

1.5Kg

Warranty Period

12 months

Output Signal

4-20mA/RS485/Passive Switch

Linked Devices

Fans, Solenoid Valves, Fire Protection Systems, etc. (24VDC/1A)

Explosion-Proof Type

Intrinsically Safe

Explosion-Proof Mark

Ex d II C T6 Gb

Operating Voltage

DC12-24V±1%

Dimensions

140L*164W*75H mm

Housing Material

Stainless Steel/Aluminum Alloy

Sampling Method

Diffusion or Pipeline Type

Temperature Rating

-40℃~+65℃ (Standard)/-40℃~+70℃ (Extreme)

Humidity Rating

15~95% RH (No Condensation)

Environmental Pressure

86kPa ~106kPa

Service Life

Over 3 years


Industry Category Instruments & Meters/Analytical Instruments/Other Analytical Instruments
Product Category
Brand: 貝斯安
Spec: BSA/QT-BJ
Stock: 999
Manufacturer:
Origin: China / Guangdong / Shenshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營(yíng)性-2023-0192
ChatGlobal Chat Now 卢氏县| 乌海市| 岳池县| 罗源县| 崇阳县| 灯塔市| 黎城县| 红安县| 铁力市| 合作市| 浦江县| 新龙县| 磴口县| 屯昌县| 犍为县| 东乡| 谷城县| 志丹县| 木兰县| 罗田县| 石棉县| 梨树县| 明溪县| 茌平县| 高青县| 阳东县| 南川市| 舞阳县| 津市市| 武穴市| 微山县| 宿州市| 林口县| 大港区| 维西| 大厂| 丰顺县| 武平县| 叶城县| 德昌县| 黔南|