尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Mixed Wood Pine Pellet Calorific Value Testing Instrument - China Supplier
China Mixed Wood Pine Pellet Calorific Value Testing Instrument - China Supplier China Mixed Wood Pine Pellet Calorific Value Testing Instrument - China Supplier

Mixed Wood Pine Pellet Calorific Value Testing Instrument

Price:Negotiable
Industry Category: Instruments & Meters/Analytical Instruments/Calorimeters
Product Category:
Brand: 鶴壁標(biāo)創(chuàng)儀器
Spec: DT-8000


Contact Info
  • Add:鶴壁市山城區(qū)朝陽街東段, Zip: 458000
  • Contact: 周經(jīng)理
  • Tel:13503920302
  • Email:

Other Products

Description
Additional Information

Mixed Wood Pine Pellet Calorific Value Testing Instrument  Mixed Wood Pine Pellet Calorific Value Testing Instrument Peanut Shell Calorific Value Testing Equipment Biomass Pellet Calorific Value Testing Instrument Biomass Fuel Calorific Value Testing Equipment, Sawdust Pellet Calorific Value Tester 

System Test Menu:

Click Ignition Test, the MCU sends an ignition command to activate the ignition circuit. Used to test the ignition circuit.
Click Stirring Test, the MCU sends a stirring command to activate stirring. Used to test the stirring circuit.
Click Water Injection Test, the MCU sends a water injection command to drive the water injection pump to work.
Click Drainage Test, the MCU sends a drainage command to drive the drainage pump to work. Can be used to add water to the instrument's outer cylinder.
Click Stop Test to end all functional tests.
3. Accurately weigh 0.9-1.0g of analytical sample with particle size ≤ 0.2mm (accurate to 0.0002g) in the crucible; for oil products, weigh 0.3~0.5g. If testing samples prone to splashing or difficult to burn, wrap the weighed sample with lens paper of known mass and calorific value, press firmly by hand, and place it in the crucible. Use one piece of lens paper, place the sample on it, wrap it tightly, and press firmly. For particularly difficult-to-burn samples, benzoic acid can be used as an additive and the oxygen charging pressure increased to 3.2Mpa. If no additive is used, enter 0 or ignore.
4. Remove the oxygen bomb cap, place the bomb head part on the bomb head stand, and install both ends of the approximately 70mm long nickel-chromium ignition wire into the electrodes, ensuring good contact. Be careful not to let the ignition wire touch the crucible or the outer wall of the bomb cylinder to avoid short circuits, which could cause ignition failure. Tie a cotton thread at the middle position to make contact with the sample in the crucible.
5. Add 10 ml of distilled water to the bomb cup, carefully place the bomb head into the bomb cup, tighten the bomb cap, and then charge with oxygen until the pressure reaches 2.8-3.0MPa. The oxygen charging time must not be less than 15 seconds. When the oxygen pressure in the cylinder is below 5MPa, the charging time should be appropriately extended. If the pressure drops below 4.0 MPa, replace it with a new cylinder of oxygen.

Loading Oxygen Bomb

Oxygen Charging

Placing Oxygen Bomb

Click Touchscreen Operation Button to Start Experiment

6. Place the oxygen-filled bomb into the inner cylinder of the calorimeter, close the calorimeter lid, click the Calorific Value Determination button to start the calorific value test. Input the sample weight and begin the experiment. The process requires no manual intervention; results are automatically displayed and printed.

Click Calorific Value InputInput the weight, number, sulfur, hydrogen, water, and other experimental data of the weighed sample. Click Return to go back to the calorific value determination interface.

Heat Capacity Calibration:

Weigh 0.9~1.1g of benzoic acid, assemble the oxygen bomb, charge with oxygen for 15~45 seconds at a pressure of 2.8~3.2MPa, place it in the inner cylinder, click "Heat Capacity Determination", input the weight of the weighed benzoic acid. After more than ten minutes, the instrument prints the calibrated heat capacity E. Repeat this 5~6 times, calculate the average value, input and save it in the system. Perform calorific value tests on 1~2 benzoic acid samples, compare the bomb calorific value with the standard calorific value; if the error is less than 120J, the calibration is successful.

Click Heat Capacity Calibration, input the sample weight, and the calibration test begins. The process requires no manual intervention; results are automatically displayed and printed.

Industry Category Instruments & Meters/Analytical Instruments/Calorimeters
Product Category
Brand: 鶴壁標(biāo)創(chuàng)儀器
Spec: DT-8000
Stock: 50
Manufacturer:
Origin: China / Henan / Hebishi
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 定西市| 大余县| 辽源市| 清新县| 甘泉县| 平远县| 阜阳市| 洪洞县| 会东县| 六枝特区| 江达县| 新宁县| 积石山| 东光县| 常宁市| 通渭县| 定襄县| 阳谷县| 定西市| 冀州市| 满洲里市| 临澧县| 阳新县| 贵定县| 东乡族自治县| 晴隆县| 大理市| 大名县| 高台县| 杂多县| 镇雄县| 陆川县| 方城县| 孙吴县| 灵石县| 乌拉特中旗| 雷州市| 周口市| 迁安市| 类乌齐县| 柯坪县|