尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Vortex Flow Meter for Natural Gas, Steam, Nitrogen, Compressed Air, Liquid, Gasoline, Sewage, Intelligent High-Precision Metering Instrument - China Supplier
China Vortex Flow Meter for Natural Gas, Steam, Nitrogen, Compressed Air, Liquid, Gasoline, Sewage, Intelligent High-Precision Metering Instrument - China Supplier China Vortex Flow Meter for Natural Gas, Steam, Nitrogen, Compressed Air, Liquid, Gasoline, Sewage, Intelligent High-Precision Metering Instrument - China Supplier China Vortex Flow Meter for Natural Gas, Steam, Nitrogen, Compressed Air, Liquid, Gasoline, Sewage, Intelligent High-Precision Metering Instrument - China Supplier China Vortex Flow Meter for Natural Gas, Steam, Nitrogen, Compressed Air, Liquid, Gasoline, Sewage, Intelligent High-Precision Metering Instrument - China Supplier

Vortex Flow Meter for Natural Gas, Steam, Nitrogen, Compressed Air, Liquid, Gasoline, Sewage, Intelligent High-Precision Metering Instrument

Price:2000~20000電議
Industry Category: Instruments & Meters/Flow Instruments/Other Flow Instruments
Product Category:
Brand: 精川
Spec: 溫壓一體化渦街流量計(jì)


Contact Info
  • Add:福建省廈門市湖里區(qū)高新區(qū)火炬東路11號(hào), Zip: 365006
  • Contact: 楊婉君
  • Tel:18059894593
  • Email:

Other Products

Description
Additional Information

I. Introduction to Xiamen Jingchuan Shares JCVF Vortex Flowmeter:

The JCVF vortex flowmeter measures the volume flow, standard condition volume flow, or mass flow of gases, steam, or liquids based on the Karman vortex principle. It can also serve as a flow transmitter in automated control systems. This instrument employs advanced differential technology, combined with isolation and filtering measures, overcoming issues such as poor shock resistance and small signal data disorder found in similar products. It utilizes unique sensor encapsulation technology and protective measures to ensure product reliability. The product comes in two forms: basic and composite. The basic type measures a single flow signal, while the composite type can simultaneously measure temperature, pressure, and flow. Each form is available in integrated and split structures to accommodate different installation environments.

II. Working Principle of Xiamen Jingchuan Shares JCVF Vortex Flowmeter:               

The vortex flowmeter consists of a vortex generator designed within the flow field, a detection probe, and corresponding electronic circuits. When fluid flows past the vortex generator, alternating rows of vortices form on both sides, known as Karman vortex streets. Based on Karman vortex street theory, Strouhal further proposed that the frequency of the Karman vortex street is proportional to the fluid velocity and provided the relationship between frequency and velocity: f

= St × V/d   Where:  

f Vortex generation frequency (Hz)

V Average flow velocity on both sides of the vortex generator (m/s)

St Strouhal coefficient (constant)                                            

These alternating vortices create a series of alternating negative pressures that act on the detection probe, generating a series of alternating electrical signals. After conversion, shaping, and amplification by the preamplifier, a pulse frequency signal (or standard signal) proportional to the vortex synchronization is output.

III. Features and Uses of Xiamen Jingchuan Shares JCVF Vortex Flowmeter:  

· No moving parts, long-term stability, simple structure for easy installation and maintenance;   

· Utilizes anti-interference circuits and vibration-resistant sensor heads, offering certain resistance to environmental vibrations;  

· Employs ultra-low power consumption microcontroller technology; a single 3.2V 10AH lithium battery can last over 5 years;   

· Software corrects nonlinearity of the meter coefficient, improving measurement accuracy;  

· Small pressure loss, wide rangeability;   

· Uses EEPROM for power-off protection of cumulative flow, with protection time exceeding 10 years;

IV. Technical Parameters of Xiamen Jingchuan Shares JCVF Vortex Flowmeter:

1. Measured medium: Steam, gas, liquid.

2. The sensor's sensing element does not directly contact the measured medium, ensuring stable performance and high reliability.

3. The sensor has no moving parts, with a simple and robust structure, small pressure loss, minimal maintenance, and long service life.

4. Rangeability up to 10:1~15:1.

5. Vortex flowmeter measurement range: Normal operating range, Reynolds number 20,000-7,000,000; output signal is unaffected by liquid temperature, pressure, viscosity, or composition. Possible measurement range, Reynolds number 8,000-7,000,000.

6. Accuracy class: Liquid, ±1.0% of indicated value; Gas, ±1.0% of indicated value; Steam, ±1.5% of indicated value.

7. Output signal: a. Voltage pulse Low level: 0-1V; High level: greater than 4V; Duty cycle: 50%;

b. Current 4-20mA (three-wire system).

8. Power supply voltage: +12VDC; +24VDC.

9. Medium temperature: Standard type a. -40℃ to +130℃; b. -10℃ to +250℃; High-temperature type a. -10℃ to +350℃; b. -10℃ to +380℃;

10. Working pressure: 0-2.5Mpa, flange clamp connection (Note: Other pressure ratings can be provided upon user request, custom-made).

11. Pressure loss: ΔP=ΔP=1.079*10-6*ρ*v2

(Where: ΔP: Pressure loss in kPa; ρ: Density of the measured medium in kg/m3; V: Flow velocity of the measured medium in m/s).

12. Housing material: Carbon steel; Stainless steel (1Cr18Ni9Ti).

13. Specifications (pipe inner diameter) 20, 25, 32, 40, 50, 65, 80, 125, 150, 200, 250, 300 (insertion type for diameters larger than DN300).

14. Ambient temperature -25℃ to +55℃; Humidity ≤85% RH.

15. Explosion-proof type: Intrinsically safe; Explosion-proof marking: iaIIcT6.

V. Measured Medium for Xiamen Jingchuan Shares JCVF:

Saturated steam, superheated steam, various gases (coal gas, air, hydrogen, natural gas, nitrogen, liquefied petroleum gas, flue gas, fuel gas, biogas, carbon dioxide, oxygen, compressed air, saturated steam, superheated steam, sulfur dioxide, ammonia, steam, liquids, and water.

Industry Category Instruments & Meters/Flow Instruments/Other Flow Instruments
Product Category
Brand: 精川
Spec: 溫壓一體化渦街流量計(jì)
Stock: 10000
Manufacturer:
Origin: China / Fujian / Xiamenshi
About Toocle.com - Partner Programme - Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 紫云| 邹城市| 秀山| 河间市| 泸定县| 平谷区| 胶南市| 万源市| 六盘水市| 沙田区| 桂平市| 马关县| 巨鹿县| 即墨市| 丰都县| 苗栗县| 砀山县| 新蔡县| 清新县| 尼玛县| 宜川县| 白朗县| 措美县| 永寿县| 遵义市| 岳池县| 九龙坡区| 蒙自县| 竹溪县| 轮台县| 商水县| 张北县| 龙州县| 本溪| 石渠县| 根河市| 南阳市| 苏尼特左旗| 枞阳县| 尉氏县| 固始县|