China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier

Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory

Price:Negotiable
Industry Category: Chemicals/Chemical Intermediates/Intermediate Compounds
Product Category:
Brand: 艾柯
Spec: Exceed-B


Contact Info
  • Add:成都市青羊區(qū)青羊工業(yè)集中發(fā)展區(qū)(西區(qū))三號園區(qū)A1棟1-2F, Zip: 610000
  • Contact: 冉經(jīng)理
  • Tel:028-87078576
  • Email:2676483902@qq.com

Other Products

Description
Additional Information

Echo Exceed Series Laboratory Ultra-Pure Water Machine

Models, Technical Parameters, Configurations

Machine Category

Exceed-Ba    Exceed-Bb

Exceed-Bc   Exceed-Bd

Machine Model

Exceed-Ba -06/12/24/32/42/50/60/80

Exceed-Bb -06/12/24/32/42/50/60/80

Exceed-BaS-06/12/24

Exceed-BbS-06/12/24

Exceed-Bc-08/16/24/32/40/60/80/100

Exceed-Bd-08/16/24/32/40/60/80/100

Exceed-Bc-S-08/16/24

Exceed-Bc-S-08/16/24

Inlet Water Source

Municipal tap water temperature 1—45℃, water pressure 1—5㎏, TDS﹤350ppm; S series is particularly suitable for high salinity areas, TDS﹤350ppm

Power Supply

220V/50HZ

Power

30W-80W

Machine Weight

25㎏-65㎏; S series 35㎏-45㎏

Main Unit Volume

Desktop: Length 450mm × Width 400mm × Height 480mm; Floor-standing: Length 450mm × Width 400mm × Height 850mm

Preparation and Water Collection Types

Dual-purpose machine, capable of simultaneously preparing and collecting two types of water quality, namely RO water and ultra-pure water

Water Quality Detection Display Configuration

Ba, Bc series equipped with three-channel, three-display, three-detection display instrument; Bb, Bd series equipped with dual-channel, dual-display, dual-detection display instrument

TOC Detection Configuration

Equipped with Exceed series dedicated Total Organic Carbon (TOC) detection display function, detection range 0~20ppb.

Water Storage Tank Configuration

Fully imported sealed vacuum pressure water storage tank: 6-32L configured with 3.2G; 40L and above configured with 11G

Ultrafiltration Membrane Configuration

Pore size 0.1μm, molecular weight cutoff 8000 dalton

Water Outlet Terminal Microfiltration

Original German imported 0.2μm capsule microfiltration (optional)

UV Configuration

None

Water Production Capacity

6L-80L per hour

8L-100L per hour

Water Collection Flow Rate

RO pure water: 1.8L/min     UP ultra-pure water: 1.5L/min

RO Pure Water Quality

Conductivity 0-10μS/cm@25℃; Impurity removal rate 99%    

Conductivity 0-15μS/cm@25℃; Impurity removal rate 98%

S series conductivity 0-4μS/cm@25℃; Impurity removal rate 99.8%

S series conductivity 0-8μS/cm@25℃; Impurity removal rate 99.5%

Water quality standard exceeds China National Laboratory Water (GB6682-2000) Grade III water standard; superior to ordinary distilled water

Ultra-Pure Water Quality

Resistivity

Resistivity 18.25ΜΩ·cm@25℃

Microparticles

(greater than 0.1μm) content: ﹤1/ml

Pyrogen

﹤0.002Eu/ml

Microorganisms

﹤1cfu/ml

Total Organic Carbon

TOC: ﹤3 ppb

TOC: ﹤5 ppb

Silicate

﹤2ppb

﹤4ppb

﹤2ppb

Metal Cation Content (ppb)

Fe (Iron) ﹤0.005     Cu (Copper) ﹤0.005   Al (Aluminum) ﹤0.005   Ni (Nickel) ﹤0.005

Zn (Zinc) ﹤0.02      Cr (Chromium) ﹤0.005   Na (Sodium) ﹤0.01    K (Potassium) ﹤0.02

Anion Content (ppb)

Clˉ (Chloride) ﹤0.01  NO2ˉ (Nitrite) ﹤0.02  NO3ˉ (Nitrate) ﹤0.02   SO42ˉ (Sulfate) ﹤0.01

Compliance Standards

China Pharmacopoeia 2010 Edition Purified Water Standard

US CAP, ASTM, NCCLS Water Quality Standards

ISO-3696 Laboratory Analytical Reagent Water Standard

China Analytical Laboratory Water Specification (GB6682-2000) Grade I Water Standard

China National Electronic Grade Ultra-Pure Water Specification (GB/T11446.1-1997) EW-I Standard

Standard Configuration

PP→AC→AC→RO→DI→UP→UF→MF

PP→AC→AC→RO→UP→UF→MF

S Series Standard Configuration

PP→AC→AC→RO→RO→DI→UP→UV→UF→MF

PP→AC→AC→RO→RO→UP→UV→UF→MF

Application Scope

Water for physical and chemical detection analysis, biochemical analysis, blood analysis, trace analysis, environmental analysis, drug composition analysis, ICP-MS, GC-MS, LC-MS, ICP, HPLC, GC, AAS, PCR, TOC, and other high-standard laboratory research, analysis, and testing in various industries


Industry Category Chemicals/Chemical Intermediates/Intermediate Compounds
Product Category
Brand: 艾柯
Spec: Exceed-B
Stock:
Origin: China / Sichuan / Chengdushi
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 开远市| 安岳县| 建德市| 洛扎县| 阿坝| 和平区| 兰溪市| 师宗县| 海城市| 芦溪县| 韩城市| 阿克| 石家庄市| 香河县| 壶关县| 三门县| 偃师市| 徐州市| 栾城县| 拜城县| 九龙坡区| 罗江县| 定南县| 牡丹江市| 西乌珠穆沁旗| 镇坪县| 鹤峰县| 石林| 临武县| 绥芬河市| 聂拉木县| 嘉祥县| 阳原县| 澄江县| 土默特右旗| 黄骅市| 登封市| 麻栗坡县| 牡丹江市| 兴仁县| 河东区|