尤物视频污,99热99热99超碰,精品久久久久女少妇,少妇精品无码,日B视屏久久香色,亚洲美女午夜福利av,国产美女被操,国产九九精品,国产久久色情

China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier
China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier China Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory - China Supplier

Ultrapure Water System for Physical and Chemical Testing and Analysis Laboratory

Price:Negotiable
Industry Category: Chemicals/Chemical Intermediates/Intermediate Compounds
Product Category:
Brand: 艾柯
Spec: Exceed-B


Contact Info
  • Add:成都市青羊區(qū)青羊工業(yè)集中發(fā)展區(qū)(西區(qū))三號園區(qū)A1棟1-2F, Zip: 610000
  • Contact: 冉經(jīng)理
  • Tel:028-87078576
  • Email:2676483902@qq.com

Other Products

Description
Additional Information

Echo Exceed Series Laboratory Ultra-Pure Water Machine

Models, Technical Parameters, Configurations

Machine Category

Exceed-Ba    Exceed-Bb

Exceed-Bc   Exceed-Bd

Machine Model

Exceed-Ba -06/12/24/32/42/50/60/80

Exceed-Bb -06/12/24/32/42/50/60/80

Exceed-BaS-06/12/24

Exceed-BbS-06/12/24

Exceed-Bc-08/16/24/32/40/60/80/100

Exceed-Bd-08/16/24/32/40/60/80/100

Exceed-Bc-S-08/16/24

Exceed-Bc-S-08/16/24

Inlet Water Source

Municipal tap water temperature 1—45℃, water pressure 1—5㎏, TDS﹤350ppm; S series is particularly suitable for high salinity areas, TDS﹤350ppm

Power Supply

220V/50HZ

Power

30W-80W

Machine Weight

25㎏-65㎏; S series 35㎏-45㎏

Main Unit Volume

Desktop: Length 450mm × Width 400mm × Height 480mm; Floor-standing: Length 450mm × Width 400mm × Height 850mm

Preparation and Water Collection Types

Dual-purpose machine, capable of simultaneously preparing and collecting two types of water quality, namely RO water and ultra-pure water

Water Quality Detection Display Configuration

Ba, Bc series equipped with three-channel, three-display, three-detection display instrument; Bb, Bd series equipped with dual-channel, dual-display, dual-detection display instrument

TOC Detection Configuration

Equipped with Exceed series dedicated Total Organic Carbon (TOC) detection display function, detection range 0~20ppb.

Water Storage Tank Configuration

Fully imported sealed vacuum pressure water storage tank: 6-32L configured with 3.2G; 40L and above configured with 11G

Ultrafiltration Membrane Configuration

Pore size 0.1μm, molecular weight cutoff 8000 dalton

Water Outlet Terminal Microfiltration

Original German imported 0.2μm capsule microfiltration (optional)

UV Configuration

None

Water Production Capacity

6L-80L per hour

8L-100L per hour

Water Collection Flow Rate

RO pure water: 1.8L/min     UP ultra-pure water: 1.5L/min

RO Pure Water Quality

Conductivity 0-10μS/cm@25℃; Impurity removal rate 99%    

Conductivity 0-15μS/cm@25℃; Impurity removal rate 98%

S series conductivity 0-4μS/cm@25℃; Impurity removal rate 99.8%

S series conductivity 0-8μS/cm@25℃; Impurity removal rate 99.5%

Water quality standard exceeds China National Laboratory Water (GB6682-2000) Grade III water standard; superior to ordinary distilled water

Ultra-Pure Water Quality

Resistivity

Resistivity 18.25ΜΩ·cm@25℃

Microparticles

(greater than 0.1μm) content: ﹤1/ml

Pyrogen

﹤0.002Eu/ml

Microorganisms

﹤1cfu/ml

Total Organic Carbon

TOC: ﹤3 ppb

TOC: ﹤5 ppb

Silicate

﹤2ppb

﹤4ppb

﹤2ppb

Metal Cation Content (ppb)

Fe (Iron) ﹤0.005     Cu (Copper) ﹤0.005   Al (Aluminum) ﹤0.005   Ni (Nickel) ﹤0.005

Zn (Zinc) ﹤0.02      Cr (Chromium) ﹤0.005   Na (Sodium) ﹤0.01    K (Potassium) ﹤0.02

Anion Content (ppb)

Clˉ (Chloride) ﹤0.01  NO2ˉ (Nitrite) ﹤0.02  NO3ˉ (Nitrate) ﹤0.02   SO42ˉ (Sulfate) ﹤0.01

Compliance Standards

China Pharmacopoeia 2010 Edition Purified Water Standard

US CAP, ASTM, NCCLS Water Quality Standards

ISO-3696 Laboratory Analytical Reagent Water Standard

China Analytical Laboratory Water Specification (GB6682-2000) Grade I Water Standard

China National Electronic Grade Ultra-Pure Water Specification (GB/T11446.1-1997) EW-I Standard

Standard Configuration

PP→AC→AC→RO→DI→UP→UF→MF

PP→AC→AC→RO→UP→UF→MF

S Series Standard Configuration

PP→AC→AC→RO→RO→DI→UP→UV→UF→MF

PP→AC→AC→RO→RO→UP→UV→UF→MF

Application Scope

Water for physical and chemical detection analysis, biochemical analysis, blood analysis, trace analysis, environmental analysis, drug composition analysis, ICP-MS, GC-MS, LC-MS, ICP, HPLC, GC, AAS, PCR, TOC, and other high-standard laboratory research, analysis, and testing in various industries


Industry Category Chemicals/Chemical Intermediates/Intermediate Compounds
Product Category
Brand: 艾柯
Spec: Exceed-B
Stock:
Origin: China / Sichuan / Chengdushi
About Toocle.com -  Toocle Partnership -  Toocle Services -  Old Version
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 马关县| 新闻| 吴旗县| 五莲县| 昆山市| 顺义区| 余干县| 石柱| 贡觉县| 辉南县| 四会市| 丰都县| 孟村| 祁连县| 湟中县| 和静县| 嘉义市| 马公市| 临潭县| 柳河县| 元朗区| 静宁县| 金堂县| 洞口县| 庐江县| 马鞍山市| 荥经县| 穆棱市| 浦北县| 仙桃市| 维西| 资溪县| 南郑县| 辰溪县| 内丘县| 池州市| 安徽省| 滁州市| 桑植县| 台前县| 金乡县|