ECS-7000MF Fan Energy Saving Controller + LCD Control Panel

Product Introduction:

The ECS-7000MF fan controller adopts microprocessor control technology, with an LCD screen displaying real-time operating status. It integrates main circuit on/off control, metering, manual/automatic control, and electrical protection into one system, ensuring stable and reliable operation. It comes with a communication port, offering good scalability and maintainability, and is installed in the ventilation/fan electrical control box.

Same Series Products:

ECS-7000MF Exhaust Fan Energy Saving Controller

ECS-7000MKT Air Conditioning/Fresh Air Unit Energy Saving Controller

ECS-7000MZM Intelligent Lighting Controller

ECS-7000MU Universal Energy Saving Controller

ECS-7000MB Water Pump/Rainwater/Sewage Pump Energy Saving Controller

ECS-7000MR Hot Water Circulation Pump Energy Saving Controller

ECS-7000MT Cooling Tower Energy Saving Controller

ECS-7000MQ Cooling Water Pump Controller

ECS-7000MD Chilled Water Pump Controller

ECS-7000MZK Cold and Heat Source Collector

Company Services:

For more product information and pricing, please call our company.

Contact: Manager Wu

Phone: 13891834587 (same number for WeChat)   

Q    Q: 407693430

Email: 407693430@qq.com

Product Features:

1. Integrates secondary circuits of ventilation/fan electrical control boxes. Combines power and control applications, eliminating the need for a separate BA control box.

2. Manual/remote-automatic control; device self-check; underground garage CO concentration monitoring; fan load rate detection, air quality monitoring, regional environmental quality monitoring; timed device start/stop control; inverter control; damper interlock control; external linkage.

3. Configurable fan types: single unit for both fire and normal ventilation, normal ventilation fan. Configurable start methods: direct start, star-delta, dual-speed start, soft start, variable frequency start.

4. Real-time tracking and recording of ventilation/exhaust fan efficiency and energy consumption data; measures three-phase voltage, three-phase current, power factor, active power, active energy.

5. Provides fault location and cause for ventilation/exhaust fans and electrical control boxes, facilitating quick maintenance.

6. Features a wide variety of I/O ports, specifically designed for air conditioning and fresh air units, meeting various control requirements.

7. Supports multiple input and output forms via pin headers and software settings.

8. Output control includes manual/auto switching and manual control functions.

Technical Parameters:

1. Product Model: YCS-7000MF

2. Auxiliary Power: DC24V

3. Detector Wiring: Communication with CO, CO2, residual pressure monitoring detectors via RS485 or two-wire bus (non-polarized).

4. Fan Control Method: Dry contact/24VDC

5. Operating Temperature: -10°C to 60°C; Storage: -25°C to 70°C

6. Operating Humidity: ≤95% RH, non-condensing, non-corrosive gas environment

7. Digital Switch Input: 16 independent switch signal input points (for fan start/stop, operating status, fault, manual/auto status monitoring, supports fire alarm and remote forced start signals, etc.)

8. Digital Switch Output: 6 independent relay output points (customizable output functions)

9. BA Communication: 1 RS485 port (polarized) for remote BA system monitoring, MODBUS-RTU protocol

10. Control Modes: Manual/remote-automatic control, time control; ventilation/exhaust fans detect actual fan status, interlock start with fire dampers; energy-saving operation via intermittent running, local exhaust, and automatic control based on garage CO concentration; smoke exhaust兼ventilation fans prioritize fire mode, automatically switching to high speed upon fire alarm input and stopping other ventilation/exhaust fans.

11. LCD Screen Real-Time Display: Device information, real-time status, alarm text, etc., with rich and intuitive content for user convenience.

Industry Category: Others
Product Category:
Brand:
Spec:
Stock:
Origin:
Storefront Language: English English Chinese
About Toocle.com -  Toocle Partnership -  Toocle Services -  Toocle Agents
Copyright ? Toocle.com. All Rights Reserved.
(浙)-經(jīng)營性-2023-0192
ChatGlobal Chat Now 西乌珠穆沁旗| 东阿县| 特克斯县| 广元市| 肃宁县| 察隅县| 吉首市| 平安县| 西乌珠穆沁旗| 凤城市| 阳江市| 克山县| 临沭县| 桦川县| 蓬溪县| 赫章县| 博湖县| 治多县| 巍山| 家居| 北安市| 晋中市| 页游| 阳原县| 巴里| 渝中区| 改则县| 玛纳斯县| 四平市| 滕州市| 迁西县| 凤山市| 合阳县| 封丘县| 巴南区| 区。| 长兴县| 平南县| 宕昌县| 微山县| 连云港市|